MULTI-AXIS MOTION SYSTEM

Dual-X Synchronous Gantry XY Hybrid System

MX-DX2-HB-01

A 2-axis positioning platform with clearly defined X and Y motion roles. Select travel, motor-side orientation, motion package and delivery scope for an engineering quotation.

MX-DX2-HB-01 Dual-X Synchronous Gantry XY Hybrid System
FIXED AXIS ARCHITECTURE

2 controlled axes with defined motion roles

The axis families and drive principles are fixed for this platform. Travel and project options are selected below.

X

X axis · BTS140S ×2

Synchronized longitudinal timing-belt axes

Timing-belt drive
Travel range
100-3050 mm
Equivalent travel per rev.
40 mm
Maximum speed
2000 mm/s
Axis repeatability
±0.04 mm
Motor reference
400 W
Y

Y axis · BSS140

Cross-travel ball-screw axis

Ball-screw drive
Standard selectable travel
250–650 mm
Ball-screw lead
20 mm
Maximum speed
1000 mm/s
Axis repeatability
±0.01 mm
Motor reference
200 W
CONDITIONAL PERFORMANCE

Performance follows the selected travel

Use the table and live summary together. Final suitability also depends on load center, acceleration and duty cycle.

Allowable payload

The current travel combination is highlighted.

Y travel (mm)250300350400450500550600650
Allowable payload (kg)1098765432
PRELIMINARY CONFIGURATION

Build a customer-readable RFQ reference

Record the information needed for quotation discussion. This reference is not a final product designation.

Travel and orientation

Y travel 100–200 mm is project-specific and requires engineering review; it is not part of the standard selector.

Motor, drive, sensing and delivery

When HS LINEAR supplies the motion package, the motor and drive are quoted together as one compatible same-brand package.

Application and requested documents
ORIENTATION & ENGINEERING DATA

Choose the motor-side orientation, then review dimensions

The direction schematic identifies the arrangement; the full-width engineering drawing carries the dimensional detail.

O1

Y left / synchronized X drive left

Direction-identification schematic. Use the drawing below for dimensions.

MX-DX2-HB-01 O1 orientation schematic
MX-DX2-HB-01 O1 engineering dimension drawing
Reference engineering dimensions
L
H
A

Dimension key

Loverall X assembly lengthHoverall installed heightAend mounting offset
Complete dimensions and permitted-speed tablesOpen by default · click to collapse

X-axis travel, mounting dimensions and permitted speed

Lettered dimensions correspond to the callouts on the full-width engineering drawing; M = number of the stated mounting-pitch intervals; N = number of mounting holes in the axis mounting pattern.

For X travel 100–350 mm, A/M/N mounting-pattern dimensions are confirmed on the approved project drawing.

X travel (mm)100150200250300350400450500550600650700750800850900950100010501100115012001250130013501400145015001550160016501700175018001850190019502000205021002150220022502300235024002450250025502600265027002750280028502900295030003050
L (mm)52957962967972977982987992997910291079112911791229127913291379142914791529157916291679172917791829187919291979202920792129217922292279232923792429247925292579262926792729277928292879292929793029307931293179322932793329337934293479
A (mm)15020050100150200501001502005010015020050100150200501001502005010015020050100150200501001502005010015020050100150200501001502005010015020050100150200
M223333444455556666777788889999101010101111111112121212131313131414141415151515
N8810101010121212141414141616161616181818182020202022222222242424242626262628282828303030303232323234343434
Maximum speed (mm/s)200020002000200020002000200020002000200020002000200020002000200020002000200020002000200020002000200020002000200020002000200020002000200020002000200020002000200020002000200020002000200020002000200020002000200020002000200020002000200020002000

Y-axis travel, installation dimensions and permitted speed

Lettered dimensions correspond to the callouts on the full-width engineering drawing.

Y travel (mm)250300350400450500550600650
H (mm)83088093098010301080113011801230
Center distance (mm)6006507007508008509009501000
Maximum speed (mm/s)100010001000100010001000100010001000

Cable-routing provision

Allow routing space for moving power, signal and sensor cables. Carrier size and installation details are confirmed with travel and delivery scope.

Selection conditions

  • Longer travel may reduce permitted speed.
  • Confirm homing, limits and cable routing with the controls package.
  • Final interface dimensions are supplied on the approved project drawing.
APPLICATION FIT

Typical motion tasks

Final suitability depends on the actual load and motion profile.

Vision inspection

Scanning and measurement across a defined work area.

Transfer and handling

Repeatable point-to-point positioning of tools or workpieces.

Dispensing and processing

Controlled path motion for dispensing, coating or light process tasks.

PRODUCT-SPECIFIC INQUIRY

Send the selected configuration